Quarter Second Electrical Detonator (aluminum or copper)-
ČSED-Al & ČSED-Cu
Usage

Quarter Second Aluminum Electrical Detonators are used for firing explosives at desired intervals and sequence, to decrease the vibration and to increase the yield of the blasting in the tunneling, especially. They are used in the environment which does not contain firedamp and other dangerous gases in.

Delay range: 1-12 No (250ms intervals)


Digression from nominal delay ČSED - Al / Cu is 112,50ms.

Cable length: On customer demand

Cable: Coated with PVC, Copper or Iron/Tin

Shell: Aluminum or Copper

Power: No.8

Transport information: UN 0255, Detonators, Electric for blasting, 1.4B

Storage:

It must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.
Millisecond Methane Safe Electric Detonator, MMSED - Cu




Usage:
Millisecond Methane Safe Copper Electric Detonators are produced with copper shell for using in mining activities which are hazardous and have risk of fire or firedamp (gas, dust, methane). The design of the detonator is fully protected from sparkling; the charge is chosen so that doesn't fire at all the mixture methane - air.
They are used only with approved methane - safe explosive.
The delay interval is chosen so that under the influence of strong resonant effect accomplish a good breakage of material and maximal usage of the power of explosive.  

Delay range: 1-18 (30, 34 ms intervals).


Table of time delays (in ms)




Digression from nominal delay: for 30 MMSED - Cu is ±13,5ms & for 34 MMSED - Cu is ±15,3ms.
Cable length: On customer demand

Cable: Coated with PVC, Copper or Iron/Tin

Shell: Copper 99%

Transport information: UN 0255, Detonators, Electric for blasting, 1.4B

Storage:
It must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.
Instantaneous Seismic Electric Detonator; TSED-Al-S1 & TSED-Al-S2

Usage:

Seismic Electric Detonators are designed for special seismic operations with burning time of electro ignition squib in 1ms. They are used for explorations for oil, gas, thermal water and drilling, underwater blasting, seismic prospecting, blasting under wet conditions.

- Delay range: Instantaneous

- Cable length: on customer demand

- Cable: Coated with PVC, Copper or Iron/tin

- Shell: Aluminum

- Power: No.8

- Sensitivity to impact 20N / 60cm;

- Temperature range: -30 to 60oC

- Tightness remains unchanged holding ED in water at a pressure of 10bar, for 48h at 20°C;

- Not for use in methane - explosive atmosphere!






Isolated Cu conductor φ1.3/0.6mm, resistance 0.06Ω/m.

Isolated Fe/Sn provodnik φ1.3/0.6mm, resistance 0.05Ω/m.

Transport information: UN 0255, Detonators, Electric for blasting, 1.4B

Storage:
It must be protected and transported in appropriate areas that dry well ventilated, without exposure to direct sunlight
Instantaneous Methane Safe Electric Detonator; TMED - Cu
Usage

Instantaneous methane safe copper electrical detonator are produced with copper shell for using in the mining activities which are hazardous and have risk of fire and firedamp (gas, dust, methane).

Delay range: Instantaneous

Cable length: On customer demand

Cable: coated with PVC, Copper or Iron/Tin

Shell: 99% Copper

Power: No.8

Transport information: UN 0255, Detonators, Electric for blasting, 1.4B

Storage:
It must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight. 
Technical Data
No ED 1 2 3 4 5 6 7 8 9 10 11 12
Shel length (mm) 67 69 71 74 76 78 80 82 84 87 89 89
Delay time
ČSED
250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000
ED 0 1 2 3 4 5 6 7 8 9 10 11 12
Shel length (mm) 52 67 69 71 74 76 78 80 82 84 87 89 89
Delay time
30-MMSED
0 30 60 90 120 150 180 210 240 270 300 330 360
  Delay time
34-MMSED

0 34 68 102 136 170 204 238 272 306 340 374 408
electric characteristics TSED - Al . S1 (Typ S1) TSED - Al . S2 (Typ S2)
bridge wire resistance (Ω) 1.4 - 2.0 0.6 - 0.8
safety misfiring current Io (A) 0.18 0.4
single firing current I1 (A) >3.00 >4.50
serial firing current I100 (A) >4.50 >6.00
firing impulse (mJ/Ω) 0.80/3.00 8.0/16
resistance to static electricity (kV/pF) 12/300 18/500
Table of delay times (ms)
Millisecond Electric Detonator, MSED - Al/Cu


Usage

Millisecond Electric Detonators are aluminum or copper detonators which can be initiated with electricity. They are used for firing the cap sensitive explosives at desired intervals and sequence, to obtain a good uniform fragmentation, the desired partical size, to decrease vibration and to increase the yield of the blasting in the great blasting operation. They are used in environment which doesn't contain firedamp and other dangerous gases in.

Delay range: 1-18 (30, 34 ms intervals)

Table of time delays in miliseconds (ms)
ED 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Lenght of shell (mm) 52 67 69 71 74 76 78 80 82 84 87 89 89 89 89 89 89 89 89
Delay time
MSED - 30
0 30 60 90 120 150 180 210 240 270 300 330 360 390 420 450 480 510 540
Delay time
MSED - 34
0 34 68 102 136 170 204 238 272 306 340 374 408 442 476 510 544 578 612
Digression from nominal delay: for 30 MSED Al/Cu is ±13,5ms & for 34 - MSED Al/Cu is ±15,3ms.

Cable length: On customer demand

Cable: Coated with PVC, Copper or Iron/Tin

Shell: Aluminum or Copper

Power: No.8

Transport information: UN 0255, Detonators, Electric for blasting, 1.4B

Storage:
It must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.
Half - Second (aluminum or copper) Electric Detonator, PSED - Al & PSED - Cu
Usage

Half Second (Aluminum or Copper) Electrical Detonators are used for mining of middle hard and soft materials. Because of the long delay intervals it comes to successive results with larger granulation, suitable for transport, the shakes are minimized to the power of one mine. For getting of the smaller granulation it is recommended the usage of quarter second detonators in combination with half second. They are used in the environment which does not contain firedamp and other dangerous gases in.

Delay range: 1-12 No (500ms intervals)
No ED 1 2 3 4 5 6 7 8 9 10 11 12
Shel length (mm) 67 69 71 74 76 78 80 82 84 87 89 89
Delay time
ČSED
250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000
Delay time
PSED
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000
Table of delay times (ms)
Digression from nominal delay ČSED - Al / Cu & PSED - Al / Cu is ±45%.

Cable length: On customer demand

Cable: Coated with PVC, Copper or Iron/Tin

Shell: Aluminum or Copper

Power: No.8

Transport information: UN 0255, Detonators, Electric for blasting, 1.4B

Storage:
It must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.
Instantaneous Electric Detonator TED (Al & Cu)
They are instantaneous aluminum or copper detonator which has to be initiated with electricity. They are used to blast in mining operations which are hazard - free and have no risk of fire and firedamp (gas, dust, methane, etc.)



Delay range: Instantaneous

Cable Length: On customer demand

Cable: Coated with PVC, Copper or Iron/Tin

Shell: Aluminum or copper

Power: No. 8

Transport information: UN 0255, Detonators, Electric for blasting, 1.4B

Storage:
It must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.







Technical Data
Technical Data
Technical Data
Technical Data
Technical Data
Technical Data
Technical Data