Non - electric Detonator BIHNEL LP







Usage

- Non - electric Detonator BIHNEL LP is suitable for underground blasting and blasting in tunnels where necessary deceleration enough to separate the materials until the next detonation;

- Not attended for the use in methane - explosive atmosphere!
Non - electric Detonator BIHNEL MS
Usage

- Non - electric Detonator BIHNEL MS is used for precise controlled mining for road built, exploration of minerals and construction on ground and underwater.

- Not attended for use in methane - explosive atmosphere!
Transport information: UN 0267, Detonators, non-electric for blasting, 1.4B

Storage:
It must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.



For the necessity of the market detonators 400ms & 500ms we manufacture also with the interval 100ms as Non-electric Initiating System UNIDET-400 and UNIDET-500.
Transport information: UN 0267, Detonators, non-electric for blasting, 1.4B

Storage:

It must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.
.


TYPE
LP0 LP1 LP2 LP3 LP4 LP5 LP6 LP7 LP8 LP9
length of
shell
(mm)
50 52 56 60 60 60 63 63 63 67
delay
time
(ms)

25 100 200 300 400 500 600 700 800 900
TYPE
LP12 LP14 LP16 LP18 LP20 LP25 LP30 LP35 LP40 LP45
length of
shell
(mm)
67 69 71 71 71 71 71 74 76 78
delay
time
(ms)

1200 1400 1600 1800 2000 2500 3000 3500 4000 4500
TYPE
LP50 LP55 LP60 LP65 LP70 LP75 LP80 LP85 LP90
length of
shell
(mm)
80 82 84 84 94 94 94 94 94
  delay
time
(ms)

5000 5500 6000 6500 7000 7500 8000 8500 9000
Surface Connector BIHNEL SL










Usage

- transfer for mining charges and following transfer by initiating of shock tube;

- it's not for usage in pits and methane - explosive atmosphere

Transport information: UN 0500, connector, non - electric, for blasting, 1.4 S

















Storage:

It must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.
type BIHNEL SL0   BIHNEL SL17
  BIHNEL SL25
  BIHNEL SL33
  BIHNEL SL42
  BIHNEL SL67
  BIHNEL SL109
  BIHNEL SL176
mark of shell A B C S D E G H
delay
time (ms)

0.2 17 25 33 42 67 109 176
color of switch GREEN YELLOW RED GREY WHITE BLUE BLACK ORANGE

Usage


BIHNEL Shock tube is a three layer plastic tube that includes reactive explosive. It allows requested lenght of BIHNEL Nonelectric detonator's shock tube to produced. It is used to fire the BIHNEL Nonelelectric ignition system instead of the ignition cable. As in electrical detonators, it is not adversely affected by environmental impacts such as electrical mediums and weather conditions. It provides high level safety in working environments.

Usage areas:

- in all underground mining and open pit mining such as dams, mines and quarries, road construction.

- the environment which does not contain firedamp and other dangerous gases in.

- use in all blasting operations in case of the static electricity and bad weather problems.

Advantages:

- the tubes are flexible, high tensile strength and resistance against abrasion.

- the connection is fast and simple.

- UV-protected, resistant to chemical agents.

- increases safety and reduces the risk from electrical currents in the field. It's not affected by static electricity.

- it can be used in any weather conditions.

Transport information: UN 0500, detonator assemblies, non - electric, for blasting, 1.4 S

Storage:

It must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.

BIHNEL Shock Tube
Non - electric Initiating System BIHNEL DUAL
sage



Non-electric initial system BIHNEL DUAL is a low-energy system for the purpose of initiating accurately controlled and complex multi-row blasting in road construction, exploitation of mineral resources and construction, on the ground and under water.

Non-electric system is recommended for a number of advantages:
- Relative electrical insensitivity;
- The possibility dotted initiation in a given place wells;
- Shock tube has no influence on the mining charge;
- Initiating the transmission of impulses with a slight sound effect;
- Minor concussion compared to the electrical system;
- Ease of use;
- Safe transport.


Initiation of non-power systems can be made as follows:
- A dedicated electronic device;
- Current electro detonator;
- Blasting cap Dk  - 6 or Dk - 8;
- Detonating cord from C5 so on;
- Start gun with the appropriate primer.







-























- Not intended for the use in methane - explosive atmosphere!

Transport information: UN 0267, Initiating system, nonelectric for blasting, 1.4 B


Store in a dry, well-ventilated warehouses at temperature of -20 to 30 ° C

Expiry date: 24 months.





Tehnical data
TYPE
MS0   MS1   MS2   MS3   MS4   MS5   MS6   MS7   MS8   MS9   MS10
  length of
shell
(mm)
50 52 55 55 57 57 60 60 63 63 65
delay
time (ms)

0 25 50 75 100 125 150 175 200 225 250
TYPE
MS11   MS12   MS13   MS14   MS15   MS16   MS17   MS18   MS19   MS20
  length of
shell
(mm)
65 65 67 69 71 74 74 74 76 78
  delay
time (ms)

275 300 325 350 375 400 425 450 475 500
Tehnical data
Tehnical data
Tehnical data
type delay time
(ms)
color of switch mark of
connector
mark of
detonator
color of
shock tube
17/500 17/500 yelow B U-500 green
25/500 25/500 red C U-500 green
42/500 42/500 white D U-500 green
Tehnical data
Dobrodošli na stranicu Pobjeda-Rudet!
Copyrights by  Pobjeda 2016. All rights reserved.