Usage Quarter Second Aluminum Electrical Detonators are used for firing explosives at desired intervals and sequence, to decrease the vibration and to increase the yield of the blasting in the tunneling, especially. They are used in the environment which does not contain firedamp and other dangerous gases in. Delay range: 1-12 No (250ms intervals)
Digression from nominal delay ČSED - Al / Cu is 112,50ms.
Cable length: On customer demand
Cable: Coated with PVC, Copper or Iron/Tin
Shell: Aluminum or Copper
Power: No.8
Transport information: UN 0255, Detonators, Electric for blasting, 1.4B
Storage
It must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.
Usage Millisecond Methane Safe Copper Electric Detonators are produced with copper shell for using in mining activities which are hazardous and have risk of fire or firedamp (gas, dust, methane). The design of the detonator is fully protected from sparkling; the charge is chosen so that doesn't fire at all the mixture methane - air. They are used only with approved methane - safe explosive. The delay interval is chosen so that under the influence of strong resonant effect accomplish a good breakage of material and maximal usage of the power of explosive. Delay range: 1-18 (30, 34 ms intervals).
Digression from nominal delay: for 30 MMSED - Cu is ±13,5ms & for 34 MMSED - Cu is ±15,3ms. Cable length: On customer demand Cable: Coated with PVC, Copper or Iron/Tin Shell: Copper 99% Transport information: UN 0255, Detonators, Electric for blasting, 1.4B
StorageIt must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.
Usage Seismic Electric Detonators are designed for special seismic operations with burning time of electro ignition squib in 1ms. They are used for explorations for oil, gas, thermal water and drilling, underwater blasting, seismic prospecting, blasting under wet conditions. - Delay range: Instantaneous - Cable length: on customer demand - Cable: Coated with PVC, Copper or Iron/tin - Shell: Aluminum - Power: No.8 - Sensitivity to impact 20N / 60cm; - Temperature range: -30 to 60oC - Tightness remains unchanged holding ED in water at a pressure of 10bar, for 48h at 20°C; - Not for use in methane - explosive atmosphere!
- Isolated Cu conductor φ1.3/0.6mm, resistance 0.06Ω/m. - Isolated Fe/Sn provodnik φ1.3/0.6mm, resistance 0.05Ω/m. - Transport information: UN 0255, Detonators, Electric for blasting, 1.4B
StorageIt must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.
Usage Instantaneous methane safe copper electrical detonator are produced with copper shell for using in the mining activities which are hazardous and have risk of fire and firedamp (gas, dust, methane). - Delay range: Instantaneous - Cable length: On customer demand - Cable: coated with PVC, Copper or Iron/Tin - Shell: 99% Copper - Power: No.8 - Transport information: UN 0255, Detonators, Electric for blasting, 1.4B
StorageIt must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.
Usage Millisecond Electric Detonators are aluminum or copper detonators which can be initiated with electricity. They are used for firing the cap sensitive explosives at desired intervals and sequence, to obtain a good uniform fragmentation, the desired partical size, to decrease vibration and to increase the yield of the blasting in the great blasting operation. They are used in environment which doesn't contain firedamp and other dangerous gases in. - Delay range: 1-18 (30, 34 ms intervals) - Delay range: 1-18 (30, 34 ms intervals)
- Digression from nominal delay: for 30 MSED Al/Cu is ±13,5ms & for 34 - MSED Al/Cu is ±15,3ms. - Cable length: On customer demand - Cable: Coated with PVC, Copper or Iron/Tin - Shell: Aluminum or Copper - Power: No.8 - Transport information: UN 0255, Detonators, Electric for blasting, 1.4B
StorageIt must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.
Usage Half Second (Aluminum or Copper) Electrical Detonators are used for mining of middle hard and soft materials. Because of the long delay intervals it comes to successive results with larger granulation, suitable for transport, the shakes are minimized to the power of one mine. For getting of the smaller granulation it is recommended the usage of quarter second detonators in combination with half second. They are used in the environment which does not contain firedamp and other dangerous gases in. - Delay range: 1-12 No (500ms intervals)
- Digression from nominal delay ČSED - Al / Cu & PSED - Al / Cu is ±45%. - Cable length: On customer demand - Cable: Coated with PVC, Copper or Iron/Tin - Shell: Aluminum or Copper - Power: No.8 - Transport information: UN 0255, Detonators, Electric for blasting, 1.4B
It must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.
Usage They are instantaneous aluminum or copper detonator which has to be initiated with electricity. They are used to blast in mining operations which are hazard - free and have no risk of fire and firedamp (gas, dust, methane, etc.) - Delay range: Instantaneous - Cable Length: On customer demand - Cable: Coated with PVC, Copper or Iron/Tin - Shell: Aluminum or copper - Power: No. 8 - Transport information: UN 0255, Detonators, Electric for blasting, 1.4B
It must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.
Usage - Non - electric Detonator BIHNEL LP is suitable for underground blasting and blasting in tunnels where necessary deceleration enough to separate the materials until the next detonation; - Not attended for the use in methane - explosive atmosphere!
Transport information: UN 0267, Detonators, non-electric for blasting, 1.4B
It must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.
Usage - Non - electric Detonator BIHNEL MS is used for precise controlled mining for road built, exploration of minerals and construction on ground and underwater. - Not attended for use in methane - explosive atmosphere!
- Transport information: UN 0267, Detonators, non-electric for blasting, 1.4B For the necessity of the market detonators 400ms & 500ms we manufacture also with the interval 100ms as Non-electric Initiating System UNIDET-400 and UNIDET-500.
It must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.
Usage - Transfer for mining charges and following transfer by initiating of shock tube; - It's not for usage in pits and methane - explosive atmosphere - Transport information: UN 0500, connector, non - electric, for blasting, 1.4 S
It must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.
Usage BIHNEL Shock tube is a three layer plastic tube that includes reactive explosive. It allows requested lenght of BIHNEL Nonelectric detonator's shock tube to produced. It is used to fire the BIHNEL Nonelelectric ignition system instead of the ignition cable. As in electrical detonators, it is not adversely affected by environmental impacts such as electrical mediums and weather conditions. It provides high level safety in working environments. Usage areas: - in all underground mining and open pit mining such as dams, mines and quarries, road construction. - the environment which does not contain firedamp and other dangerous gases in. - use in all blasting operations in case of the static electricity and bad weather problems. Advantages: - the tubes are flexible, high tensile strength and resistance against abrasion. - the connection is fast and simple. - UV-protected, resistant to chemical agents. - increases safety and reduces the risk from electrical currents in the field. It's not affected by static electricity. - it can be used in any weather conditions. Transport information: UN 0500, detonator assemblies, non - electric, for blasting, 1.4 S
It must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.
Usage Non-electric initial system BIHNEL DUAL is a low-energy system for the purpose of initiating accurately controlled and complex multi-row blasting in road construction, exploitation of mineral resources and construction, on the ground and under water. Non-electric system is recommended for a number of advantages: - Relative electrical insensitivity; - The possibility dotted initiation in a given place wells; - Shock tube has no influence on the mining charge; - Initiating the transmission of impulses with a slight sound effect; - Minor concussion compared to the electrical system; - Ease of use; - Safe transport.
Initiation of non-power systems can be made as follows: - A dedicated electronic device; - Current electro detonator; - Blasting cap Dk - 6 or Dk - 8; - Detonating cord from C5 so on; - Start gun with the appropriate primer. Not intended for the use in methane - explosive atmosphere! Transport information: UN 0267, Initiating system, nonelectric for blasting, 1.4 B Store in a dry, well-ventilated warehouses at temperature of -20 to 30 ° C Expiry date: 24 months.
It must be protected and transported in appropriate storage areas that dry well ventilated, without exposure to direct sunlight.
Usage This type of connectors is used for mining with detonating cord, when delay time between detonations of single mining charges is required; by which shakes during explosions are decreased. - Not attended for the use in methane - explosive atmosphere!
Usage Mining of dry surface and underground workplaces, by which it comes to full detonation of several explosive charges, meaning the full explosive effect.
Transport information: UN 0029, Detonating cap for blasting, 1.1B
in dry, well ventilated storehouses on temperature from - 25 to 40 oC